Page 82

Energética India | September / October 2015

PRODUCTS MobilHybrid for Power Generators MobilHybrid for Power Generators helps to save up to 50% diesel and reduces maintenance costs up to 60%. The MobilHybrid is switched between diesel generator and consumers. It can optionally be supplemented by 8 kWp solar panels with connectable module output to save further on diesel. The MobilHybrid is available in 3 sizes and 6 power levels to cover all mobile power needs. Features • Reliable power and cost effective way to integrate renewable energy sources • Uninterruptable power Supply • Real-time online monitoring system and generation data • Compatible with existing diesel generator • Fuel efficiency is improved. • Capable of handling starting current 3 times of rated capacity • Diesel savings of up to 50 % • Operating cost savings 60% • Payback periods less • 2 years in part load operation • Smaller power generator power with power boost feature • Less noise emissions • 30 % lower CO2 emissions • Dimensions of a euro pallet • Optional energy supply by photovoltaic Application • Construction • Mining • Defence • Telecom • Renewable Energy Integrations • Fire Fighting • Oil and Gas Explorations • Events • Mini-grid and Island Grid • Rural Electrification • Food processing • Data centres Specifications Type MH-3 MH -4 MH-8 MH-12 MH-18 MH-24 Size A A B B C C Continuous power VA bei 25°C 2000 3500 6000 10500 15000 21000 Top performanceVA bei 25° 30 Min 2600 4000 7800 12000 18000 24000 Top performance VA 25°C 5 sec 6500 10500 19500 31500 45000 63000 Output voltage V AC 230 V 230 / 400 V Input courage max. AC 32A 50A 50A Max .Output current (with external AC source ) A 16A (32A) 28A (44A) 46A (63A) 63A Protection functions Overload,over temperature, short circuit ,discharged batteries Earth fault 40A 1ph 30mA FI 63A 3ph 100mA FI Usable battery capacity kWh 3.0 5.5 11 16.5 22.0 Usable battery capacity kWh CEE 32A 1ph CEE 63A 3ph Output Connector A A CEE 32A 1ph 2x Schuko 16A IP54 3x Schuko 16A IP54 Output Connector B 1 * Schuko 16 A CEE 63A 3ph Charging time at the net to full charge 2.5h 2.5h 2.5h Auxiliary contact ( remote start Dieselgen.) Phoenix Battery monitoring LCD Display:Voltage,Power,State of charge,runtime, load cycle Startup time 5 minutes Protection IP44 Operating temperature range (-)10°C bis + 45°C Dimensions W x D x H mm 600 x 800 x 1200 800 x 1200 x 1290 800 x 1200 x 1690 Weight kg ca. 240 480 690 1360 1380 Optional Photovoltaic loader Controller with up to 8kWp connectable module output 80 energetica INDIA · SEP | OCT15


Energética India | September / October 2015
To see the actual publication please follow the link above